Sign In | Join Free | My himfr.com
Home > Detection Reagent >

Universal Viral Transport Collection Kits Disposable Sampler Swab Sterile Type

    Buy cheap Universal Viral Transport Collection Kits Disposable Sampler Swab Sterile Type from wholesalers
     
    Buy cheap Universal Viral Transport Collection Kits Disposable Sampler Swab Sterile Type from wholesalers
    • Buy cheap Universal Viral Transport Collection Kits Disposable Sampler Swab Sterile Type from wholesalers
    • Buy cheap Universal Viral Transport Collection Kits Disposable Sampler Swab Sterile Type from wholesalers
    • Buy cheap Universal Viral Transport Collection Kits Disposable Sampler Swab Sterile Type from wholesalers

    Universal Viral Transport Collection Kits Disposable Sampler Swab Sterile Type

    Ask Lasest Price
    Brand Name : discuss
    Model Number : discuss
    Certification : CE,FDA,SGS
    Price : negotiable
    Payment Terms : T/T
    Supply Ability : 10000pcs per day
    • Product Details
    • Company Profile

    Universal Viral Transport Collection Kits Disposable Sampler Swab Sterile Type

    Universal viral transport collection kit/Disposable sampler / Swab Instruction Manual-for COVID-19 test

    video for instruction manual: https://v.youku.com/v_show/id_XNDYwNTAxOTk5Ng==.html



    1. Product name
    Common name: Disposable sampler
    2. Specifications
    1 person set / pack, 20 persons set / box, 30 persons set / box,
    50 persons set / box, 100 persons set / box.
    3. Main structure and performance
    It usually consists of a swab and / or a cup, tube, etc. containing a preservation solution. Sterile
    type.
    4. Scope of application
    For sample collection, transportation and storage.
    5. Contraindications, Precautions, Warnings, Instruction
    (1). The disposable sampler should be sent for inspection as soon as possible after sampling, and
    immediately transported at 2-8 ° C. The collected samples can be placed at 2-8 ° C for a short
    period of 48 hours; long-term storage should be placed at low temperature below -20 ° C, Store at
    70 ° C or -196 ° C.
    (2). This product is strictly forbidden for sampling of bacterial samples. The antibiotics contained in
    the preservation solution can inhibit bacteria.
    (3). It is forbidden to directly contact the collected patient, and it is forbidden to sample the
    patient after wetting the swab.
    (4). Sampling should be performed strictly in accordance with the sampling procedure, so that the
    sampling location is accurate and the sampling intensity is uniformly suitable, otherwise it will
    affect the quality of sample collection.
    (5). Do not use the product after its expiration date or its packaging is damaged.
    6. How to use
    (1). Medical institutions or users can sterilize sampling tubes and swabs before use.
    (2). Mark the relevant sample information on the sampling tube and inject an appropriate amount
    of sample preservation solution.
    (3). According to different sampling requirements, use a sampling swab to sample at the
    corresponding location, hold the handle and gently insert the sampling swab into the sampling site,
    gently rotate the sampling swab 3-5 times, and then slowly remove it.
    (4). Put the extracted sample into the sampling tube, break the part of the sampling swab that is
    higher than the sampling tube, then tighten the tube cap tightly and seal it to complete the
    sampling.
    (5). Freshly collected clinical specimens should be delivered to the laboratory within 48 hours at 4 °
    C. If they are not delivered to the laboratory within 48 hours, they should be stored at -70 ° C or
    below. Specimens should be inoculated and separated as soon as possible after being sent to the
    laboratory, and those that can be inoculated and separated within 48 hours can be stored at 4 ° C.
    If it cannot be inoculated, it should be stored at -70 ° C or below.
    (6). There are several conventional sampling methods:
    2a) Nasal swab: Gently insert the swab head into the nasal condyle inside the nasal passage, and
    then slowly turn it out after staying for a while. Wipe the other nostril with another swab, immerse
    the swab head in the sampling solution, and discard the tail.
    b) Pharyngeal swab: Wipe bilateral pharyngeal tonsil and posterior pharyngeal wall with the swab.
    Also immerse the swab head in the sampling solution and discard the tail.
    c) Mouthwash: Rinse the mouth with 10mL of normal saline."Oh", let the normal saline rotate in
    the pharynx, and collect the lotion with a 50mL empty sampling tube.
    d) Nasal wash solution: The patient takes a sitting position, tilts his head back, and injects 50mL of
    normal saline into one nostril with a pipette, and instructs the patient to make a K sound at the
    same time to close the pharynx. Then let the patient lower their heads to let the saline flow out,
    collect the lotion with a 50mL empty sampling tube, and repeat the process to wash the nostrils on
    both sides.
    e) Nasopharyngeal extracts: Tracheal and bronchial secretions are often collected using this
    method. Mucus is extracted from the nasopharynx using a collector connected to a negative
    pressure pump. First insert the collector head into the nasal cavity, turn on the negative pressure,
    rotate the collector head and push it out slowly. Collect and extract mucus, and rinse the collector
    three times with 5 mL of collection solution.
    f) Autopsy tissue specimens: When necessary, autopsy tissue specimens are collected for sample
    component separation. The specimen was autopsy tissue.
    g) Sampling of Mycoplasma, Chlamydia, Ureaplasma specimens: Male: Insert a sterile cotton swab
    into the urethra about 2 cm to rotate, take a few seconds to take the material. Female: Wipe off
    cervical mucus, insert 1-2cm of cervical canal with sterile swab to take material.
    7. Storage conditions
    Store at normal temperature, store in a dry and ventilated place, avoid moisture, not with
    poisonous or special smell.
    Store the items together and avoid direct contact with fire sources and flammable and corrosive
    substances.
    8. Validity
    18 months
    Quality Universal Viral Transport Collection Kits Disposable Sampler Swab Sterile Type for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: XIAN NING HUAXIN GP HEALTHCARE SAFETY PROTECTIVE PRODUCTS CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)